2017819(土)

Light scattering receiving optics

The surface of the part is subjected to high energy UN light, which causes electrons to be emitted. It is another expensive test, though. With this method there is a visual identification of the contamination present on the part. Light scattering receiving optics or extinction detectors gather the redirected or diffracted energy and create a raw sensor output for each particle. A reputable cleanliness testing lab will have a variety of methods encompassing many types of testing. That is why it is imperative to seek the help of a qualified lab to conduct proper testing, prior to the purchase of cleaning equipment. Another drawback is that only contaminants that exhibit fluorescence in the UV range of the camera are documented. With proper testing, a wash process can be designed to meet any reasonable cleanliness specification.For production part manufacturers, cleaning specifications are a major concern when setting up a line. However, it is a subjective test. First, there is visual analysis alone. Millipore testing is a commonly used objective measurement standard for cleanliness specifications. The equipment is costly- $10,000 to $30,000. Since many parts have specifications in the microns, the human eye is virtually worthless. When dealing with that small of contamination, it is difficult to trust the eyes of an observer. Like the particle counter, it is expensive technology. The results are expressed in particles per fluid volume or particles per part.
It is also inexpensive, and can even be implemented into the manufacturing process as a part of the line. The more information, the better a washing process can be designed to meet the needs of the manufacturer. This report should detail the specifics of the contamination found in the testing, and ideally will offer a process by which to reduce contamination. Clean surfaces emit more electrons than unclean surfaces in this test.00. The part is first washed in an aqueous or sealed solvent system and passes a cursory subjective cleanliness review like those listed above. f-stop and time. OSEE has excellent repeatability, is able to accurately quantify minute levels of contamination and is founded upon solid scientific principles. The specifications can be rigid, difficult to understand, and tough to meet for many manufacturers.Microscopy is used to examine minute particles. Cleaning specifications have numerous effects on production, planning, and the ultimate success of a job. This is a quantitative methodology that few companies Ultrasonic Sprayer外部リンク are in possession of. OSEE is the Optically Stimulated Election Emission test. This method can quantify large quantities of particulates quickly and indicate particles within certain ranges.. OSEE is also unable to identify specific contaminants; it simply can tell if there is contamination. A CCD camera compares clean and dirty parts using photographs. The parts are photographed using the same photographic variables, i. Another testing method is particle counting. It can be used for particle counting, but the process is subjective and tedious. They are observed for fluorescence, which determines the contaminant level of the part.e. These will encompass qualitative, quantitative, subjective, and objective methods of testing, allowing for a comprehensive study of the part.
These reports are vital for distilling the information found in testing into a more digestible form. The part is washed as it is with the Millipore testing and then rinsed or cleaned with an ultrasonic bath. Also, bubbles in the sample are occasionally counted as particles.Testing helps manufacturers gain a clear understanding of how clean their parts need to be, and lays the groundwork for determining how to get there.After the testing has been conducted, the manufacturer should receive a laboratory report. The part is then rinsed with a solvent to remove all the contaminant that had remained on the part after cleaning, is collected and filtered through a pre-weighed membrane that has a specified micron rating. Cost is an issue with this test as well, ranging up to a $100,000. They set the parameters for the type of washer that will be used, they determine what chemicals and steps will be necessary within the washing process, and keeping the customer pleased depends on meeting or exceeding the guidelines. However, regimented, standardized testing techniques must be repeated and followed throughout the process in order for this testing to be valid. The membrane with the contaminant, which is greater than the size of the specified micron rating, is dried and weighed. Black light/UV Testing exposes clean and dirty samples to a 254nm and 365nm light. The net weight equals the overall amount of contaminant left on the part. Human visual analysis, using no instruments, is entirely subjective and unreliable. Computer software is then used to produce a histogram of pixel intensities, with higher intensities indicating a higher level of contamination. The solution is then introduced to laser by way of an automated pressure-sampling device. Millipore testing is common, inexpensive, objective and provides semi-quantitative information. A human hair is 70-100 micros in width, and many parts have to be free of particles that are slightly larger than that. The individual determines cleanliness; there is no objective analysis performed by a machine or data received. The reflected electrons are then measured.






 コメント(0件)コメント欄はユーザー登録者のみに公開されます 
コメント欄はユーザー登録者のみに公開されています

ユーザー登録すると?
  • ユーザーさんをお気に入りに登録してマイページからチェックしたり、ブログが投稿された時にメールで通知を受けられます。
  • 自分のコメントの次に追加でコメントが入った際に、メールで通知を受けることも出来ます。






 カウンター
2017-08-01から
563hit
今日:1


戻る